cosmetic tube filling sealing machine Questions and Troubleshooting

The following explains some common problems of the filling and sealing machine. Before analyzing the specific problems, 

cosmetic tube filling sealing machinemust be checked and tested as follows:

1. Check whether the actual running speed of the Cosmetic Plastic Tube Sealer Filler   is the same as the manual initial debugging speed;

2. Check whether the Leicester heater is in the open position;

3. Check whether the compressed air supply pressure of the Cosmetic Plastic Tube Sealer Filler  meets the pressure requirements when the equipment is working normally;

4. Check whether the cooling water is unblocked and whether the temperature of the cooling water is within the range required by the Cosmetic Plastic Tube Sealer Filler

5. Check whether the paste falls off during the filling process of the filling and sealing machine, especially to ensure that the paste will not stick to the upper part of the inner wall of the pipeline;

6. Do not touch anything on the inner surface of the hose, so as not to pollute the inner surface of the hose;

7. Check whether the air inlet of Leicester heater is normal;

8. Check whether the temperature detector inside the heater is in the correct position;

9. Check whether the heating head ventilation device is working normally;

Analyze some common specific problems of cosmetic tube filling sealing machine

Question 1: When phenomenon 1 appears on the left, it is usually caused by excessive temperature. At this time, you should check whether the actual temperature is the temperature required for the normal operation of the standard Tube

The actual temperature on the temperature indicator should be relatively stable at the set temperature (the normal deviation range is between 1°C and 3°C).

Question 2: One ear phenomenon: first check whether the heating head of cosmetic tube filling sealing machine correctly placed in the heating head cover, and then check the verticality of the heating head and the hose below,

Another possible cause of side ears is a misalignment of parallelism between the two tailgates. The deviation of tail plate parallelism can pass 0.2~0. This test uses a 3 mm shim.

Problem 3: The sealing tail  of cosmetic tube filling sealing machine in the middle of the hose is cracked. This phenomenon occurs because the heating head is not large enough. Please change to a bigger one,

The standard for judging the size of the heating head is to insert the heating head into the hose and then pull it out, and feel a slight suction when pulling it out.

Question 4: There are "eye bags" under the explosion-proof line of the sealing end: this situation is caused by the incorrect height of the outlet of the heating head,

Problem 5: The middle part of the tube tail is sunken: This problem is usually caused by the wrong size of the tube, the tube  is clamped too tightly in the cup, the standard for judging the size of the tube,

The hose should be fully clamped in the cup, but the cup should not interfere with the natural change in shape of the hose when the tail is clamped.

Smart zhitong is a comprehensive and cosmetic tube filling sealing machine packaging machinery and equipment enterprise integrating design, production, sales, installation and service. It is committed to providing you with sincere and perfect pre-sales and after-sales services to benefit the field of chemical equipment @carlos